Free tool

Bounce house generator and extension cord calculator

Enter the amps on your blower labels to see the generator size you need, how many blowers one household circuit carries, and the extension cord gauge that keeps the blower running at full power over your run.

A blower starved of voltage runs hot and can let the inflatable soften. Sizing the power before the event avoids a tripped breaker mid-party.

Everything is worked out in your browser. What you type is not sent to us or saved.

Your blowers

Read the amps from each blower's label or manual. Add a row for each blower size.

Optional. Lights, fans, a speaker.

Power at the site

Household circuit breaker

Optional. From the outlet or generator to the blower.

Planning figuresCommon allowances. Your generator's manual wins.

Blower motors draw a surge as they start.

3% is the usual target for a branch circuit.

Result

Enter the amps from your blower's label. The generator size, how many blowers one circuit carries and the cord gauge for your run appear here as you type.

This is an estimate, not electrical advice. Follow your blower and generator manuals and local electrical code, and ask a licensed electrician when in doubt.

The method

How it works

  1. Read your blower labels

    Enter the amps printed on each blower's label or in its manual, and how many of each size you are setting up.

  2. Add anything else on the same power

    Lights, fans or a speaker plugged into the same generator or circuit add to the load.

  3. Describe the site

    Pick the household circuit breaker size and enter how long the extension cord run is.

  4. Read the result

    See the generator's running and starting ratings, how many blowers one circuit carries, and the cord gauge for your run.

Read the guide behind it

More free tools

Frequently asked questions

Add up the running watts (amps on the label times 120 volts), and pick a generator whose running rating keeps that load at or below about 80% of the rating. Its starting rating must also cover the surge as each blower motor starts. Switching blowers on one at a time keeps that surge down.

A circuit should carry no more than 80% of its breaker rating for a continuous load: 12 amps on a 15 amp circuit, 16 amps on a 20 amp circuit. Two outlets on the same breaker share that limit, so find which outlets are on separate circuits.

It depends on the blower's amps and the length of the run. Longer runs lose more voltage, which makes blower motors run hot. The calculator picks the thinnest gauge that keeps the drop within 3%, using standard copper resistance figures.

Avoid it. Each connection adds resistance and a place for water to get in. Use one outdoor-rated cord of the right gauge and length, plugged into a GFCI-protected outlet.

Wire resistance is from the National Electrical Code (Chapter 9, Table 8, stranded copper). The 80% continuous load and 3% voltage drop are the usual planning limits. The blower's own amps always come from you.